Titre de la page
Français
Site map
Contacts
Help
Login
×
Close
Contacts
BERNARD Julie
Qualification & Sourcing Referent
+33 (0)4 42 95 95 95
+33 (0)4 42 95 95 00
NOVEL Aurélien
Correspondant CCTR
+33 (0)6 65 83 15 33
+33 (0)4 42 95 95 00
FONTAN Guillaume
FNP Catalog Owner
+33 (0)6 15 85 22 22
+33 (0)4 42 95 95 00
Name
*
Email
Your request concerns
*
Choose
FNP website functions
EDF Reference documents
Coating systems published on FNP catalog
Object
*
Message
*
Captcha
*
Send
×
Close
Site map
Homepage
FNP systems
Published systems FNP list
Reference document
List of document reference
List of useful links
Codification list
Company
Companies list
Are you sure you want to log out?
Homepage
FNP systems
Published systems FNP list
Reference document
List of document reference
List of useful links
Codification list
Company
Companies list
>
List of FNP systems
>
Visualize FNP system
Visualize a published system sheet
×
This system is undergoing redevelopment and its use may possibly be subject to conditions
FNP system
FNP number
Index FNP
Last publication
state
Company
Choose
AKZO NOBEL POWDER COATINGS
ARKEMA
BELZONA
CARBOLINE
CHESTERTON
GEHOLIT
HEMPEL
HENKEL
INTERDESCO
INTERNATIONAL PEINTURE
JOTUN
MAESTRIA
MAX PERLES
MC CHIMIE
MIVA COATINGS SLU
PLASTOCOR
PPG
RESIPOLY CHRYSOR
SIKA FRANCE
SPPM
TEGG
Total thickness
public comment EN
Sept. 9th, 2022 : The qualification scope of FNP1114 coating system is extended to PIC serie (localisation inside HR building) for EPR units. ******** NOTA ******** The final selection by a project or a worksite of a PIC coating system qualified for accident conditions (PCC RRC-A) may depend on the results of evaluation under severe accident conditions (release of debris, residual performance of the coating) **************** May 16th, 2022 : The qualification scope of FNP1114 coating system is extended to PIC serie (localisation inside HR building) for REP units in exploitation only. ENDUIT PANTOXY NF COATING : In the case of concretes with significant bubbling, an optional 3rd coat of Enduit Pantoxy NF may be necessary in particular to meet the requirements of the PIC and PID codes. While rendering is optional for 152 -154 groups code, it may be needed depending on the state of the substrate after surface preparation. For PIA/PIB/PID codes only : ENDUIT PANTOXY NF applicable to airless gun and roller then smoothing with spatula
Utilities type
Thermique
Hydraulique
INTRADOS
EXTRADOS
PIC EPR
PIC REP
PARC NUCLEAIRE
Technical sheet
FNP 1114 ENG - Ind F - July 2022.pdf
Codification:
Codifications published
PIA/EIA
PIB/EIB
PID/EID
PIC
154
PIA/EIA
PIB/EIB
PID/EID
PIC
152
PIA/EIA
PIB/EIB
PID/EID
PIC
151
PIA/EIA
PIB/EIB
PID/EID
PIC
155
Coat list
Coat number
Product name
Thickness
Nature of the binder
Type of phase
Proportion of solvent
1
ENDUIT PANTOXY NF GRIS CLAIR
303 g/m²
Epoxy-polyaminoamide
AQ
2
ENDUIT PANTOXY NF GRIS CLAIR
280 g/m²
Epoxy-polyaminoamide
AQ
3
HYDROCENTRIFUGON PEINTURE NF IVORY RAL 1015
40 µm
Epoxy-polyaminoamide
AQ
4
HYDROCENTRIFUGON PEINTURE NF WHITE RAL 9010
40 µm
Epoxy-polyaminoamide
AQ